Honeycomb Air Vents:
Shielded Enclosures are a confined space and ventilation is an important requirement. To provide air flow into the enclosure
and still maintain the shielding integrity, special vents are required. These vents are constructed using a metallic
honeycomb wafer soldered into a steel frame. A minimum of two air vents are required for each enclosure, with one providing
the fresh air entry and the other the exhaust.
Power Filters:
Power Filters are used to attenuate signals traveling along the power cabling as it passes into the RF shielded enclosure.
A two line 32A mains power filter is normally supplied with each enclosure, however the filter configuration can be varied
to cater for client requirements including 3 phase, different supply frequency, Voltage, Current, Leakage to earth and
Performance.
Penetration Panel:
In order to pass physical connections such as coaxial cables, fibre optic cables and DC power and signal lines into an RF
shielded enclosure a Penetration Panel is required. The penetration panel can be configured to client requirements with
N type coaxial connectors, brass waveguide penetrations and signal/power filters.
Finger Strip and Gasket materials:
Beryllium Copper (BeCu) contact finger strip is applied to the RF shielded enclosures door frame to create an RF seal
with the door. Compliance Engineering can supply a range of beryllium copper (BeCu) contact finger strip, specialised
RF gaskets and conductive adhesive tape for use in your shielding application.